Transmit pulse shape pulse width 0.45ms ± 0.1ms (mode A/C)
pulse width 0.5ms ± 0.05ms (mode S)
rise time 0.05 to 0.1ms
fall time 0.05 to 0.2ms
Nominal output impedance 50 W
D. Environmental conditions in accordance
with EUROCAE/RTCA ED-14D/DO-160D
Input voltage range 10.0 to 33.0 V DC
Low operating temperature -20 °C
High operating temperature +55 °C
High short-time operating temperature +70 °C
Storage temperature range -55 °C to +85 °C
In-flight loss of cooling Cat. Z, no auxiliary cooling required
Altitude 50,000 ft. max. (class 1)
15,000 ft. max. (class 2)
Humidity Cat. A / +50° C; 95%, 48 h
Vibration resistance Cat. S, test curve M
Cat, U, test curve G
Operational shocks 6 g in any direction
Crash safety 20 g shocks
20 g acceleration
Magnetic effect Category Z
Environmental categories:
Env.Cat. [D1Z]BAB[(SM)(UG)]XXXXXXZBABA[WW]B[A3E3X]XXA
INSTALLATION AND OPERATION BXP6401-X-(XX)
Page 1-5