Installation Instructions 
 
 
 
Power Supply Connection 
 
The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is 
located on the PC housing in order to connect the power supply. 
 
Socket at the PC housing 
 
 
Technical data  Connecting socket 
Number of contacts 
5  
Contact spacing 
5 mm 
Minimum conductor cross-section 
1.5 mm² 
Minimum conductor cross-section 
(AWG) 
16 
Rated voltage (EN) 
250 V 
Rated voltage (CSA) 
300 V 
Current EN [A] 
12 A 
Current CSA [A] 
15 A 
Length of stripped conductor 
8 to 9 mm 
 
 
Supplied mains power unit 
The Industrial PCs is either fitted with a 100-240 V, 50-60 Hz power supply 
unit (standard) or with a 24 V
DC
 power supply unit (with the option of an 
uninterruptible power supply, UPS).  
 
 
Current carrying capacity of the 100-240 V power supply 
unit 
 
C6110, C6120, C6130
 
 
 Output voltages from 
the 100-240 V power 
supply unit
Current loading  
maximum 
 
+3.3 V  14 A 
 
+5 V stand by 
1.5 A 
 
+5 V 
16 A 
 
-5 V 
0.2 A 
 
+12 V 
9 A 
 
-12 V 
0.7 A 
 
 
C6140, C6150
 
 
 Output voltages from 
the 100-240 V power 
supply unit
Current loading  
maximum 
 
+3.3 V 
16 A 
 
+5 V stand by 
2 A 
 
+5 V 
25 A 
 
-5 V 
0.3 A 
 
+12 V 
13 A 
 
-12 V 
0.8 A 
 