EasyManuals Logo

Beckhoff CP6700-0001-00 0 Series User Manual

Beckhoff CP6700-0001-00 0 Series
28 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #12 background imageLoading...
Page #12 background image
Product Description
10 CP6700-0001-00x0/ CP6706-0001-00x0
2.4.5 Protective Earthing (PE)
The low-resistance protective earthing of the Panel PC is established via the screw connection (PE).
CAUTION
Protective Earthing (PE)
The protective conductor connection must not be used for other potentials. “PE” and
“0V” (24V system power supply) must be connected to the same potential (connected
in the control cabinet).
The wiring in the control cabinet must occur in accordance to the standard
EN 60204-1:2006 (PELV = Protective Extra Low Voltage).
EN 60204-1:2006 part 6.4.1: b): One side of the circuit or one point of the power
source must be connected to the protective earth conductor system.
CAUTION
Breaking the Power Supply/ Shutting down
Never disconnect the ground connection when switching off the device. Always
disconnect the 24V cable, other wise electricity can still flow due to the screen in
dependence of the device.
Any connected devices with its own power supply must have the same potential for
“PE” and “GND” like the Panel PC system (no potential difference).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Beckhoff CP6700-0001-00 0 Series and is the answer not in the manual?

Beckhoff CP6700-0001-00 0 Series Specifications

General IconGeneral
BrandBeckhoff
ModelCP6700-0001-00 0 Series
CategoryTouch Panel
LanguageEnglish

Related product manuals