PN JR-IM-10AG
October 2014
Instructions For Use
Rotors and Tubes
For Beckman Coulter
J2, J6, and Avanti J Series Centrifuges
Beckman Coulter, Inc.
250 S. Kraemer Blvd.
Brea, CA 92821 U.S.A.

Table of Contents

Questions and Answers:

Beckman Coulter Avanti J-26 XP Series Specifications

General IconGeneral
BrandBeckman Coulter
ModelAvanti J-26 XP Series
CategoryLaboratory Equipment
LanguageEnglish

Summary

Rotors and Tubes

Safety Notice

Alerts for Warning, Caution, Important, and Note; Chemical and Biological Safety; Mechanical Safety; RoHS Notice.

CHAPTER 1 Rotors

Rotor Selection

Guides users on how to select the appropriate rotor for their application.

Rotor Balance

Explains the importance and methods for balancing rotors.

Rotor Tie-Down

Describes how to secure rotors to the centrifuge drive spindle.

CHAPTER 2 Tubes, Bottles, and Accessories

Labware Selection Criteria

Factors to consider when choosing tubes, bottles, and accessories for centrifugation.

CHAPTER 3 Tubes, Bottles, and Accessories

General Filling and Sealing or Capping Requirements

General guidelines for filling and sealing tubes and bottles.

Working with Physiological Fluids

Safety precautions and containment for handling physiological fluids.

CHAPTER 4 Using Fixed-Angle Rotors

CHAPTER 5 Using Swinging-Bucket Rotors

Prerun Safety Check

Safety checks before using swinging-bucket rotors.

Symmetric and Balanced Loading

Explains how to achieve symmetric and balanced loading of buckets/carriers.

Sample Recovery

Methods for recovering samples from swinging-bucket rotors.

CHAPTER 6 Using Vertical-Tube and Rack-Type Rotors

Rotor Preparation and Loading

Steps for preparing and loading rack-type rotors.

Prerun Safety Checks

Safety checks for rack-type rotors.

Installing the Rotor

Guide for installing rack-type rotors onto the centrifuge spindle.

Removal and Sample Recovery

Procedures for removing rack-type rotors and recovering samples.

CHAPTER 7 Care and Maintenance

Rotor Care

General principles for maintaining rotors in optimal condition.

Cleaning

Procedures for cleaning rotors and their components.

Decontamination

Methods for decontaminating rotors exposed to hazardous materials.

Sterilization and Disinfection

Recommended methods for sterilizing and disinfecting rotors and components.

Inspection

Guidelines for inspecting rotors for damage or wear.

Diagnostic Hints

Troubleshooting common operating problems with centrifuges and rotors.

APPENDIX A Chemical Resistances for Beckman Coulter Centrifugation Products

APPENDIX C Gradient Materials

APPENDIX D Blood Component Separation

Separation of Blood Components by Centrifugation

Explains centrifugation methods for separating blood components.

Tips for Optimum Centrifugation Runs

Provides tips for safe and efficient blood component centrifugation.