Creating a new program
1. Switch on the unit. The current temperature of
the furnace is displayed after approx.
3 seconds.
2. Select program:
Press as often until LED # lights up.
Press until desired program number
appears.
3. Call up programming mode:
Keep button depressed until LED "°C/min."
flashes.
4. Call up and set the parameters at holding
level 1:
Press to call up the following param-
eters
heating-up speed (°C/min),
temperature of the holding level (°C),
duration of the holding level (min)
(the relevant LED flashes).
Press to set the values of the param-
eters.
5. To set the next holding level, go to the
field using the buttons and call up the next
holding level using the buttons.
Set the parameters at this holding level as
described in point 4.
6. Exit the programming mode:
Keep button depressed until LED "°C" lights
up.
NOTE
You should keep a note of your own programs.
The tables in this documentation are provided
for this purpose.
Set up the „care program” at program location 9
(see section “Service and Maintenance”,
page 46):
Heating-up speed "0°C/min.",
temperature of holding level: 1050°C,
duration of holding level: 60 minutes.
Holding levels 2 to 4: all values = 0!
Always set all holding levels! All values in the
unused holding levels of a program must be set
to "0".
Heating-up speed "0°C/min." = maximum heat-
ing-up speed!