Fig. 3 Installation Regulus
WARNING
Installation, site of Installation
and start-up
Install unit only on adequately sta-
ble and non-combustible surface.
Because of the wax vapours, install
the furnace under a chimney stalk
as far as possible. Always dis-
charge vapours outdoors.
Only use the furnace in dry rooms.
There must not be any combustible
objects in the area near the fur-
nace.
There must not be any highly flam-
mable or explosive gas, liquids or
solid material in the same room as
the furnace.
WARNING
Danger due to electric shock
Prior to the electrical connection
check whether the specifications on
the rating plate correspond to the
power supply network. In the case
of uncertainty, consult an electri-
cian.
Always connect the furnace to a
separate circuit with 16-ampere
fuse protection.
The machine is subject to the provi-
sions of class of protection I and
may only be connected to properly
grounded power sources.
Use the rear plug only for connect-
ing the Regulus furnace suction
extraction unit (REF 25750,
200…240 V).
If moulds are to be preheated using
the shock heat method, the Regulus
furnace extraction system must be
installed!