Installation, site of Installation
and start-up
• Install unit only on adequately sta-
ble and non-combustible surface.
• Because of the wax vapours, install
the furnace under a chimney stalk
as far as possible. Always dis-
charge vapours outdoors.
• Only use the furnace in dry rooms.
• There must not be any combustible
objects in the area near the fur-
nace.
• There must not be any highly flam-
mable or explosive gas, liquids or
solid material in the same room as
the furnace.
Danger due to electric shock
• Prior to the electrical connection
check whether the specifications on
the rating plate correspond to the
power supply network. In the case
of uncertainty, consult an electri-
cian.
• Always connect the furnace to a
separate circuit with 16-ampere
fuse protection.
• The machine is subject to the provi-
sions of class of protection I and
may only be connected to properly
grounded power sources.
• Use the rear plug only for connect-
ing the Regulus furnace suction
extraction unit (REF 25750,
200…240 V).
• If moulds are to be preheated using
the shock heat method, the Regulus
furnace extraction system must be
installed!