Program table
Up to 9 programs can be stored with Miditherm
(#1 to #9).
Up to 4 temperature holding levels can be set in
each program ( to ).
The following must be set at each holding level:
• heating-up speed (0 to 9 °C/min.),
• temperature of the holding level (max. 1150 °C)
• duration of the holding level (max. 99 min.).
The cut-out temperature of the connected Regulus
furnace extraction system can be set for each
program. The factory setting (600 °C) is adequate
for customary investment materials that are heated
up slowly. For shock heat investment materials, the
Regulus furnace extraction system must be set to
continuous operation (→ page 39).
Five standard programs are factory-set for BEGO
alloys. The programs can be overwritten as
required.
Your own programs should be noted. The tables in
this documentation (please make copies) serve this
purpose.
• In programs with fewer than 4 temperature
holding levels set all values of the following
holding levels to "0".
• The furnace heats up at maximum speed when
the heating-up speed is set to "0°C/min.".
• In seldom cases of lower power supply and
above 800 °C, the heating-up speed may not
be achieved.