English
Miditherm MP
37
85817 BA-en/12 306.01269…/307.00804…
en
Program table
Up to 9 programs can be stored with Miditherm
(#1 to #9).
Up to 4 temperature holding levels can be set in
each program ( to ).
The following must be set at each holding level:
heating-up speed (0 to 9 °C/min.),
temperature of the holding level (max. 1150 °C)
duration of the holding level (max. 99 min.).
The cut-out temperature of the connected Regulus
furnace extraction system can be set for each
program. The factory setting (600 °C) is adequate
for customary investment materials that are heated
up slowly. For shock heat investment materials, the
Regulus furnace extraction system must be set to
continuous operation ( page 39).
Five standard programs are factory-set for BEGO
alloys. The programs can be overwritten as
required.
Your own programs should be noted. The tables in
this documentation (please make copies) serve this
purpose.
NOTE
In programs with fewer than 4 temperature
holding levels set all values of the following
holding levels to "0".
The furnace heats up at maximum speed when
the heating-up speed is set to "0°C/min.".
In seldom cases of lower power supply and
above 800 °C, the heating-up speed may not
be achieved.