The chamber is evacuated during preheating.
The preheating may last for up to 60 seconds.
NAUTILUS
®
alerts the operator with an acous-
tic signal and a message on the display that
the preheating process has ended.
7. Have the mould readily available before press-
ing the "OK" button to prevent the alloy from
cooling down unnecessarily. Preheating tem-
perature and vacuum are maintained until
then.
8. Close the mould door.
The next display is shown when the mould
door is closed.
9. Confirm the melting process by pressing the
"OK" button or exit the program by pressing
the "Abort" button.
In fast mode, the preheating process starts
upon closing the mould door.
WARNING
Risk of burns!
Use mould tongs!
WARNING
Never look into the melt without
protective glass and protective
eyewear!