EasyManuals Logo

Bego Nautilus T User Manual

Default Icon
88 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #52 background imageLoading...
Page #52 background image
52
86105 BA-en/00
English Nautilus
®
CC plus
en
Manual casting with pyrometer
Manual casting (with pyrometer) is usually only
needed to check and correct preheating and casting
temperatures. This is, for instance, required when
setting up new programs for non-BEGO alloys (see
page 30).
1. Select the alloy (see page 41).
2. Go to "Settings" > "Program" > ""Pyrometer".
3. Optional: Enter log data (see "Setting up the
protocol" on page 40). This data appears in the
casting protocol that is stored on the con-
nected USB flash drive.
Enter work number, batch and casting quan-
tity and confirm the entry with "OK" or
Skip the data entry with "Abort".
4. Insert the alloy.
5. Close the crucible door.
6. Confirm the preheating process with "OK".
For some alloys, the preheating process may
be skipped with a second button.
In fast mode, the preheating process starts
upon closing the crucible door.

Other manuals for Bego Nautilus T

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bego Nautilus T and is the answer not in the manual?

Bego Nautilus T Specifications

General IconGeneral
BrandBego
ModelNautilus T
CategoryDental equipment
LanguageEnglish

Related product manuals