The PRO-800 can be taken out of its factory chassis and
tted into a standard Eurorack case (not supplied).
We recommend that this procedure is carried out only by an
experienced service technician to prevent personal injury or
damage to the PRO-800. The Eurorack case will need to have
a suitable power supply with enough capacity to power the
PRO-800. Consumption is 1.2 A at 12 v DC.
A 10 pin to 16 pin adapter ribbon cable is supplied with the
PRO-800.
Please ensure that the Eurorack case will supply +/- 12v DC
and ground to the correct pins, and that the cable is at the
correct orientation before proceeding.
Procedure
Please follow all steps in the correct order.
1. Disconnect the power and all other connections to
the PRO-800.
2. Undo the eight screws on the top panel as shown.
There is no need to undo any other screw.
3. Carefully lift the top panel assembly, and turn it over so
that the PCB is facing upwards. Be careful not to pull the
ribbon cable from the lower side of the main PCB.
4. Disconnect the 24 pin ribbon cable from the main PCB of
the PRO-800 and remove the assembly from the chassis.
5. Store the chassis assembly and power supply in a safe,
dry place.
6. Securely connect the 10 pin end of the supplied ribbon cable
adapter to the main PCB of the PRO-800.
7. Having ensured that your Eurorack case is isolated from
the mains connect the 16 pin end of the ribbon cable to a
spare outlet in the case.
8. Secure the PRO-800 to the case using the eight
panel screws.
9. Perform a full safety test before using the PRO-800.