Table of Contents

Questions and Answers

  • G
    gcurtisAug 14, 2025
    What to do if my BEKA PICO-troniX1 does not operate?
    • N
      Nancy MercadoAug 14, 2025
      If your BEKA Water Pump isn't working, there could be several reasons. First, check if the pump is getting power by renewing the fuse if installed. If the fuse is fine, inspect the electric line for any breaks and renew if needed. If power isn't the issue, the pump itself or the integrated control unit might be defective, requiring replacement.
  • M
    Michael PotterAug 17, 2025
    What to do if my BEKA Water Pump operates but does not deliver?
    • C
      Cynthia KentAug 18, 2025
      If your BEKA Water Pump runs but doesn't pump anything, it might be due to a few reasons. You may have an airlock in the delivery piston or air in the reservoir, in which case you should ventilate the pump. Also, check if the reservoir is empty and fill it up if needed. A defective level switch or pump element can also cause this problem, requiring you to exchange the control unit or the pump element.
  • M
    Margaret ReyesAug 21, 2025
    Why is lubricant leaking at the pressure limiting valve of BEKA Water Pump elements?
    • A
      ana37Aug 21, 2025
      If you find lubricant leaking at the pressure limiting valve of your BEKA Water Pump elements, it could be due to several reasons. The system pressure might be too high, so you should check the system. Alternatively, the progressive distributor could be blocked, requiring you to exchange the distributor. A blocked system, which requires you to repair blocked bearing, or a broken valve spring, which requires you to change the pressure limiting valve, could also be the cause.
  • D
    drew89Aug 25, 2025
    What to do if my BEKA PICO-troniX1 is not switched off despite reservoir is empty?
    • L
      Laura EvansAug 25, 2025
      If the BEKA Water Pump is not switching off even when the reservoir is empty, it's likely due to a defective level switch or integrated control unit. In either case, you'll need to exchange the control unit.
  • T
    Tiffany ValentineAug 27, 2025
    What to do if my BEKA Water Pump shows a level error but the reservoir is filled with lubricant?
    • J
      James DavisAug 27, 2025
      If your BEKA Water Pump is showing a level error even though the reservoir is full, it indicates either a defective level switch or a defective integrated control. In both cases, the solution is to exchange the control unit.
  • H
    hernandezleslieAug 30, 2025
    Why is there no grease at some lube points with my BEKA PICO-troniX1 Water Pump?
    • M
      Megan RodriguezAug 31, 2025
      If some lube points aren't getting any grease from your BEKA Water Pump, check the lines of the secondary distributor for bursts or leaks and exchange the line if needed. Also, inspect the fittings for leaks and retighten or change the fitting.
  • R
    Renee GonzalezSep 3, 2025
    Why is there no grease at one lube point with my BEKA Water Pump?
    • M
      mary83Sep 3, 2025
      If only one lube point isn't getting grease from your BEKA Water Pump, inspect the lubrication line for bursts or leaks and exchange the line if necessary. Also, check the fitting for leaks and retighten or change the fitting.
  • R
    Robert KennedySep 7, 2025
    Why is the speed of my BEKA PICO-troniX1 reduced?
    • D
      Diana CaseySep 7, 2025
      If your BEKA Water Pump's speed has reduced, it could be due to high system pressure. Check the system and bearing point for damage, and perform intermediate lubrication 1-2 times. Another possibility is that the supply voltage is too low, so you should check the voltage.
  • M
    Mitchell BrownSep 10, 2025
    What to do if function of BEKA PICO-troniX1 do not match the set values in the control unit window?
    • C
      corymolinaSep 10, 2025
      If the function of your BEKA Water Pump (operating mode, cycle duration, or lubrication duration) doesn't match the set values in the control unit window, it's possible that the operating mode or setting of the control unit has been changed, but the old label was not replaced with the new one. To fix this, perform a diagnose by means of BEKA-DiSys software and have the setting correct according to the label, or change the label.

Summary

General Safety Instructions

Safety Guidelines, Hazards, and Operator Obligations

General safety rules, symbols, hazards from non-compliance, and operator responsibilities.

Specific Safety Precautions

Safety for maintenance, modification, operation modes, ESD, and hazard notes.

Regulatory Compliance and Guarantee

Use in Accordance with Regulations

Guidelines for operating the pump according to regulations and intended use.

PICO Pump Setup and Function

Pump Assemblies and Operational Mechanism

Describes pump assemblies and the operational mechanism of the PICO pump.

Level Monitoring and Control Unit PICO-troniX1

Level Monitoring and Unit Functions

Level monitoring, unit functions, signals, data base, and parameter settings for PICO-troniX1.

Control Unit PICO-tronic

Unit Functions, Modes, and Special Features

Functions, modes, special features, error messages, and parameter changes for PICO-tronic.

Assembly and Installation

Start-up, Lubricants, and Ventilation

Maintenance

Repair

Replacing the Integrated Control Unit

Step-by-step guide to replacing the integrated control unit.

Troubleshooting

Error Diagnosis and Remedies

Common errors and their solutions for pump operation, delivery, and control unit issues.