EasyManua.ls Logo

BEKA FKGGM-EP - User Manual

Default Icon
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Central lubrication pump
Article-no. 2076 . ......
FKGGM-EP / EPR V DC
FKGGM-EP / EPR VAC
FKGGM-EP with installed MX-F distributor
- without control unit
- with integrated control unit EP-tronic 2157. .....
- with integrated control unit BEKA-troniX1 2175. .....
- with integrated control unit EP-tronic ZX 2060. .....
- with integrated control unit EP-tronic ZX - S1 2060. .....
- with integrated control unit EP-tronic ZX - S2 2060. .....
State of art: 01 / 2019
Original operating
and
assembly instructions
1
Subject to alterations!
...a product from
BAL2076_central lubrication pump_0119EN
© BEKA 2019 All rights reserved

Table of Contents

Other manuals for BEKA FKGGM-EP

Questions and Answers

  • W
    william75Jul 25, 2025
    What to do if BEKA Lubrication systems pump operates but does not deliver?
    • B
      Brandon HallJul 25, 2025
      If your BEKA Lubrication system pump operates but doesn't deliver lubricant, it might be due to a low lubricant level. Refill the reservoir. Alternatively, the pump may need to be ventilated or the pump element exchanged.
  • S
    sosamelissaJul 31, 2025
    Why does my BEKA Lubrication systems pump show a level error?
    • R
      Rita LoveAug 1, 2025
      If your BEKA Lubrication system pump shows a level error, it could be due to the lubricant level being too low. In this case, refill the reservoir. Alternatively, the level switch or cable may need to be replaced.
  • I
    ihollandAug 6, 2025
    Why is the speed of my BEKA Lubrication systems pump reduced?
    • B
      bvazquezAug 6, 2025
      If your BEKA Lubrication system pump speed is reduced, it could be due to high system pressure. Check the system and bearing points. It could also be due to a low supply voltage, so check the voltage.
  • C
    Catherine AndersonAug 12, 2025
    Why is lubricant coming out of the safety valve on my BEKA Lubrication systems?
    • M
      martinezdavidAug 12, 2025
      If lubricant is coming out of the safety valve of your BEKA Lubrication system, it could be because the system pressure is too high. In this case, check the system. Other potential solutions include replacing the distributor, repairing blocked or stuck bearing points, or exchanging the safety valve.
  • R
    rmeltonAug 18, 2025
    How to fix no grease at one lubrication point in BEKA Lubrication systems?
    • N
      Nicholas DeanAug 18, 2025
      If there is no grease at one lubrication point in your BEKA Lubrication system, the lubrication time (pump runtime) might be too low. Adjust the lubrication time (PLC). Alternatively, the main line may need to be renewed, or the distributor exchanged.

Summary

General Information and Safety

Intended Use

Specifies the allowed applications for the central lubrication system.

Safety Instructions

Provides essential safety notes, warnings, and hazard information.

Owners Obligations

Details the responsibilities of the operator and owner for safe operation.

Technical Data and Functional Description

General Technical Data

Covers reservoir capacity, operating ranges, sound levels, and installation position.

Pump Functionality

Describes the operation of FKGGM-EP and FKGGM-EPR pumps.

Pump Element Function

Details the function and types of pump elements used in the system.

Installation, Accessories, and Control Units

FKGGM-EP Installation Dimensions

Provides dimensional drawings for various FKGGM-EP pump reservoir sizes.

FKGGM-EPR Installation Dimensions

Provides dimensional drawings for various FKGGM-EPR pump reservoir sizes.

Level Monitoring Accessories

Explains the connection and function of level monitoring sensors and switches.

Control Unit Types and Functions

Describes general control unit functions, types, and collective fault signals.

Assembly, Start-up, and Filling

Pump Installation Position

Specifies correct installation positions for FKGGM-EP and FKGGM-EPR pumps.

General Start-up Procedures

Highlights essential checks before pump start-up and sense of rotation.

Electrical Connections

Details electrical connection methods for various pump and control unit configurations.

Basic Filling Procedures

Instructions on how to initially fill the pump reservoir with lubricant.

Maintenance, Repair, and Troubleshooting

Preventive Maintenance and Lubricant Exchange

Outlines checks for wear parts, lubricant levels, and exchange procedures.

Troubleshooting Pump Operation

Provides solutions for when the central lubrication pump does not operate.

Component Exchange Procedures

Details procedures for exchanging distributors, pump elements, and handling errors.

Fault Diagnosis and Elimination

Lists common faults, their possible causes, and elimination methods.

BEKA FKGGM-EP Specifications

General IconGeneral
BrandBEKA
ModelFKGGM-EP
CategoryWater Pump
LanguageEnglish

Related product manuals