BAL2076_central lubrication pump_0119EN
© BEKA 2019 All rights reserved
Central lubrication pump FKGGM - EPR:
Compare the sense of rotation of the central lubrication pump by a visual control with the direction arrow on the
level label! Remove the ventilation screw (fig. 47) from the pump housing. Check the sense of rotation of the
pump by means of the vent screw opening, use a lamp if necessary.
Fig. 47:
Check the sense of rotation and the connection in the terminal and change it if necessary.
Ventilation screw
Lamp
Opening of ventilation screw
7. Start-up
Observe the following items before the pump start-up in order to guarante a perfect function
of the pump.
The electric connection may only be done at switched off supply voltage.
Assemble the electric lines away from hot parts (max. 50°C) and avoid chafe marks.
Alonger operation with the wrong sense of rotation can damage motor and pump.
The electric connection of the pump must only be done by professionals. The electric
components have to be wired professional. Compare the voltage details with the available
mains voltage.
Central lubrication pump FKGGM - EP:
Compare the sense of rotation of the agitator blade with the direction arrow on the level label.
If the sense of rotation is wrong, check the connection of the terminal box.
Attention!