EasyManua.ls Logo

Belling BI 60 MF - Step 2: Connect to Electricty Supply

Belling BI 60 MF
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
Step 2: Connect to the electricity
supply
This appliance must be connected by
a competent person, using f ixed
wiring via a double pole switched
fused spur outlet, wit h a contact
separation of at least 3mm in all poles.
Connection should be made with
suitable twin & earth heat resistant
flexible cable, minimum 1.5mm
2
, which
is suitable for use up to 13 amps.
USE A 13 AMP FUSE
We recommend that the appliance is
connected by a qualified electrician,
who is a member of the N.I.C.E.I.C.
and who will comply with the I.E.E.
and local regulations.
Warning: This appliance must be
earthed.
As the colours of the wires may not
correspond with the coloured markings
identifying the terminals in your spur
box, proceed as follows:
1. The wire which is coloured green
and yellow must be connected to
the terminal marked E (Earth) or
coloured green.
2. The wire which is coloured blue
must be connected to the terminal
marked N (Neut ral) LOAD or
coloured Black.
3. The wire which is coloured brown
must be connected to the terminal
marked L (Live) LOAD or coloured
Red.
INSTALLATION INSTRUCTIONS
Use a 13 amp fuse
Live
Earth
N supply L Load
N Load
13
FUSE
ON
Typical example of a double
pole fused spur outlet
Cable
Neutral
250
~