EasyManua.ls Logo

Bematech I-500 - Code Identifiers

Bematech I-500
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I-500 Imaging Barcode Scanner
29
PROGRAMMING GUIDE
Example, set Suffix string to "END"
1. From the ASCII code character table, the hexadecimal values of the string "END" is
"45", "4E", "44".
2. Confirm that programming of scanner is enabled.
3. Scan "Modify Suffix" barcode.
4. Scan the 8 data setting bardcodes in Appendix B, "4", "5", "4", "E", "4", "4".
5. Scan the "Save Settings" barcode.
Code Identifiers
Adding code identifiers to the output stream allow applications to identify the
symbologies of barcodes read. The single character code identifier Code ID corresponding
to each barcode type can be modified according to application requirements.
Enable Code ID Output
* Disable Code ID Output
Restore all Code ID to default
Save Settings