EasyManua.ls Logo

Bematech LB-1000 - Hour

Bematech LB-1000
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
?.+
Description
This variable reads/writes the hour data via the Real Time Clock (RTC). The 24-hour-day system
(00~23) is supported by RTC. @HOUR global variable can be accessed directly without using BASIC
language functions.
Syntax
Write attribute: @HOUR = "12"
Read attribute: @HOUR
Range: 00~23
Model Support
LB
-
1000
Example
REM *****Set @HOUR*****
@HOUR="23"
REM *****Print*****
SIZE 3,3
GAP 0.08,0
DENSITY 8
SPEED 6
DIRECTION 0
REFERENCE 0,0
SET CUTTER OFF
SET PEEL OFF
CLS
TEXT 10,10,"5",0,1,1,"@HOUR"
TEXT 310,10,"5",0,1,1,@HOUR
PRINT 1
See Also
~!C, @YEAR, @MONTH, @DATE, @DAY, @MINUTE, @SECOND

Other manuals for Bematech LB-1000