Connection
For UL application................................................................................................use 60/70 °C copper conductors only
Connection type.......................................................................................................... screw-type terminals
Connection properties:
rigid/ flexible/ conductor sizes ................................................................. 0.2…4 / 0.2…2.5 mm
2
/ AWG 24…12
Multi-conductor connection (2 conductors with the same cross section)
rigid, flexible ....................................................................................................................... 0.2…1.5 / 0.2…1.5 mm
2
Stripping length ............................................................................................................................................ 8…9 mm
Tightening torque.................................................................................................................................... 0.5…0.6 Nm
Connection type............................................................................................................ push-wire terminals
Connection properties:
Rigid .......................................................................................................................... 0.2…2.5 mm
2
( AWG 24…14)
Flexible without ferrules......................................................................................... 0.75…2.5 mm
2
( AWG 19…14)
Flexible with ferrules ................................................................................................. 0.2…1.5 mm
2
( AWG 24…16)
Stripping length .................................................................................................................................................. 10 mm
Opening force........................................................................................................................................................... 50 N
Test opening, diameter....................................................................................................................................... 2.1 mm
Other
Operating mode ........................................................................................................................... continuous operation
Position of normal use................................................................................................................................................any
Protection class, internal components (DIN EN 60529)..........................................................................................IP 30
Degree of protection, terminals (DIN EN 60529).................................................................................................... IP 20
Enclosure material....................................................................................................................................polycarbonate
Flammability class.............................................................................................................................................UL94V-0
DIN rail mounting acc. to................................................................................................................................. IEC 60715
Screw mounting .................................................................................................................. 2 x M4 with mounting clip
Weight ............................................................................................................................................................... ≤ 150 g