Technical data VMD460-NA
80
VMD460-NA_D00001_05_M_XXEN/01.2020
Contact data acc. to IEC 60947-5-1:
Utilisation category .......................................................................................... AC 13 AC 14 DC-12 DC-12
DC-12
Rated operational voltage................................................................................230 V 230 V 24 V 110 V 220 V
Rated operational current ................................................................................ 4 A**/5 A 3 A 1 A 0.2 A 0.1 A
** Rated operational current for UL508 and CSA C22.2
Minimum contact rating ....................................................................................................................... 1 mA at AC/DC ≥ 10 V
Environment/EMC
EMC ............................................................................................................................................... DIN EN 60255-26 / CEI 0-21
Operating temperature ....................................................................................................................................... -25…+55 °C
Classification of climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) ................................................................... 3K5 (except condensation and formation of ice)
Transport (IEC 60721-3-2) .......................................................................... 2K11 (except condensation and formation of ice)
Long-term storage (IEC 60721-3-1) .......................................................... 1K22 (except condensation and formation of ice)
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3)............................................................................................................................................3M4
Transport (IEC 60721-3-2)................................................................................................................................................... 2M4
Long-term storage (IEC 60721-3-1) .................................................................................................................................1M22
Connection
Connection type................................................................................................screw-type terminals (or push-wire terminals)
Connection properties:
Rigid............................................................................................................................................ 0.2…4 mm
2
(AWG 24…12)
Flexible .................................................................................................................................. 0.2…2.5 mm
2
(AWG 24…14)
Stripping length...........................................................................................................................................................8…9 mm
Tightening torque........................................................................................................................... 0.5…0.6 Nm (5…7 lb-in)
Other
Operating mode ........................................................................................................................................ continuous operation
Mounting ................................................................................................................................................................. any position
Degree of protection, internal components (DIN EN 60529) ............................................................................................. IP30
Degree of protection, terminals (DIN EN 60529) ................................................................................................................ IP20
Enclosure material................................................................................................................................................ polycarbonate
Flammability class........................................................................................................................................................ UL94 V-0
DIN rail mounting acc. to..............................................................................................................................................IEC 60715
Screw mounting .............................................................................................................................................................. 2 x M4
Software version measurement technology ............................................................................................................ D398 V1.2x
Software version display ...........................................................................................................................................D403 V2.2x
Weight .............................................................................................................................................................................≤ 360 g