Autostacker™ Parking Lift 28 P/N 5900002 — Rev. D — August 2019
To connect the Hydraulic Hoses:
1. Locate the two Hydraulic Hoses that come with your Lift.
2. Starting near the Console, route the Long Hydraulic Hose through the Bottom Connector Tube
and pull it out at the Hydraulic Cylinder that is furthest away from the Console.
Leave enough Hose on the Console end to allow the Long Hydraulic Hose to be connected to the
Power Unit up through one of the openings at the bottom of the Console.
Pull out enough of the Hydraulic Hose to reach the Connector with Two Nuts when it is time to put
all of the components together.
3. Starting near the Console, route the short Hydraulic Hose through the Bottom Connector Tube
and pull it out at the Hydraulic Cylinder nearest to the Console.
Leave enough of the Hydraulic Hose on the Console end to allow the Short Hydraulic Hose to be
connected to the Power Unit up through one of the openings at the bottom of the Console.
Pull out enough of the Hydraulic Hose to reach the Connector with Two Nuts when it is time to put
all of the components together.
4. For both Hydraulic Cylinders, install Velocity Fuses in the connectors near the bottom of each
Hydraulic Cylinder. Finger tighten the connection.
Refer to About Velocity Fuses for more information.
5. For both Hydraulic Cylinders, remove one Nut from the Connector with Two Nuts, put the
Connector with Two Nuts into the Connector Weldment, put the Nut you just removed back onto
the Connector with Two Nuts, and finger tighten both Nuts around the Connector Weldment.
6. For both Hydraulic Cylinders, connect the Hydraulic Line Assembly to the top end of the Connector
with Two Nuts and the other end to the top end of the Velocity Fuse.
Finger tighten all connections.
7. For both Hydraulic Cylinders, connect the Hydraulic Hose to the bottom end of the Connector with
Two Nuts.
Finger tighten the connections.
8. Attach two 90° connectors (FTB ELB -04 JIC -06L ORB) to both Hydraulic Power connectors on
the Power Unit.
There are two Hydraulic Power connectors on a Power Unit, in varying locations (depending on the
Power Unit you have). Refer to Connect the Power Unit to identify your layout.
9. Route the two Hydraulic Hoses, one at a time, through an opening along the bottom of the
Console and up to one of the 90° connectors, then connect them. It does not matter which
Hydraulic Line goes to which Hydraulic Power connector.
10. Once all connections have been made, use the appropriate tools to fully tighten all of the finger-
tightened connections.