Autostacker™ Parking Lift 66 P/N 5900002Rev. D August 2019
DANGER All wiring
must
be performed only by a licensed, certified Electrician. Do not
perform any maintenance or installation on the Lift without first making sure that
main electrical power has been disconnected from the Lift and cannot be re-
energized until all procedures are complete. If your organization has
Lockout/Tagout policies, implement them after connecting to a power source.
To connect to a power source:
1. Have a certified, licensed Electrician connect an appropriate plug to the wiring, coming out of the
Power Unit.
The plug is not supplied with the Power Unit.
2. Connect the power source cable to the plug you just connected.
The power source cable is not supplied with the Power Unit.
Refer to Wiring Diagrams for wiring information.
3. Connect the Control Stands to the Power Unit.
Refer to Wiring Diagrams for wiring information.
4. Connect the Power Disconnect Switch.
Refer to Wiring Diagrams for wiring information.
5. Have a certified, licensed Electrician check for any loose connections.
6. Fill the Hydraulic Fluid Reservoir.
The Power Units Hydraulic Fluid reservoir must be filled with Hydraulic Fluid or Automatic
Transmission Fluid before you begin operation. When you receive it, the reservoir is empty; the
Power Unit will not work correctly until there is an adequate supply of the approved fluids.
Approved fluids are any general purpose ISO-32, ISO-46, or ISO-68 hydraulic oil or approved
automatic transmission fluids such as Dexron III, Dexron VI, Mercon V, Mercon LV, or any synthetic
multi-vehicle automatic transmission fluid.
WARNING Do not run the Power Unit without Hydraulic Fluid; you will damage it. Keep the
Power Unit dry; damage the Power Unit caused by water, detergents, acids, and
other liquids is not covered by the warranty.