1.2 Maintenance and Cleaning
Before switching on, please check if the exposed window is clean, if it is dirty clean
it promptly.
After using the device, check the optics. If it is contaminated, please clean it
promptly.
The optics should be cleaned regularly if the device be operated in a severe
environment for a long time.
Before regular cleaning, please disconnect the power. Using a soft cloth to gently
wipe the window in the same direction when the device is not operating, to avoid
repeated wiping and damage to the LiDAR window.
When cleaning the window, do not use alcohol to clean, so as not to damage the
window.
If you require deep cleaning of internal optics, please contact bw@benewake.com
to offer professional advice.
1.3 Appearance and Structure
The appearance and dimensions of TF02-Pro are shown in Figure 1-1 and Figure 1-2:
① The detection range is determined with the standard white board (90%
reflectivity).
② The frame rate can be adjusted. The default value is 100Hz and the maximum
value is 1000Hz, the customized frame rate should be calculated by the
formula: 2000/n (n is an integer with ≥ 2).
③ The angle is a theoretical value, the actual angle value has some deviation.