Do you have a question about the Bentone B 10 E R and is the answer not in the manual?
Identifies and labels the various parts of the oil burner assembly.
Provides dimensional drawings and flange size details for different burner models.
Details recommended nozzle sizes, capacity, and type for various output ranges.
Illustrates electrode gap settings and air regulation graph for optimal combustion.
Outlines regulations, installer responsibilities, and safe handling during installation.
Guides on adjusting the burner for optimal combustion, including air and flue gas settings.
Explains the risk of chimney condensation and methods to mitigate it.
Covers regular examination for malfunctions and instructing the end user on operation.
Step-by-step guide for servicing the burner head, including component removal.
Details methods for suspending the burner and cleaning the fan wheel.
Identifies electrical components and provides a detailed wiring diagram.
Illustrates the external electrical connections for the burner and boiler.
Explains the sequence of operations for the oil burner control system.
Details safety cut-out times and procedures for burner restart attempts.
Provides technical specifications like pre-ignition time, safety lock-out time, and ambient temperature.
Lists technical specifications, viscosity, pressure range, and components of the pump.
Provides tables for suction line length calculations and instructions for purging.
Explains how the pump draws oil, pressurizes it, and regulates pressure.
Discusses oil quantity reduction during preheating and related factors.
Detailed guide on how to remove and replace the pump's cartridge filter.
Troubleshooting steps for situations where the burner does not initiate operation.
Addresses issues preventing the burner from starting after a period of normal use.
Diagnoses and remedies for delayed ignition or unusually strong burner starts.
Explains the role of the pressure switch and its recommended type (Dungs LGW3A2).
Details the physical connection to the boiler and its electrical wiring in series.
Illustrates wiring diagrams for pressure switch integration with various burner control models.
Covers boiler room cleanliness, safety switch checks, and pre-start valve/damper status.
Addresses issues with burner ignition failure and provides guidance for summer shutdown.
Highlights critical safety advice, including avoiding inspection doors during start-up.
| Type | Oil burner |
|---|---|
| Voltage | 230 V |
| Frequency | 50 Hz |
| Phase | Single phase |
| Fuel | Light oil |