2-11
Electrical Installation
88
88A
85
86A
86B
Connect Battery Management System
to Battery Separator Solenoid This 3
wire harness from the 8 pin connector
routes to the battery separator solenoid.
Cut wires to length, crimp snap fork
terminals on each wire and connect to
designated terminals. This switch
separates the Aux batteries from the
starting batteries. It closes when the truck
batteries are at or above 13.2 and opens at
12.5 volts. Location can be in the AUX
battery box, truck starting battery box or
the supplied plastic enclosure.
This harness must be loomed.
Notice: the terminal connecting points
are printed on each wire.
Terminals are marked as:
88 Starting battery cable (POS)
88A Aux battery cable (POS)
85 Solenoid common (White wire)
86A solenoid disengage (Tan wire)
86B solenoid engage (Orange wire)
19
Orange
White
Tan