Bernina 1230 - Test K; Foot Control Resistance Test

Bernina 1230
39 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
What
is
to
be
tested
What
to
adjust
Normal
condition
Foot
control
When
a
fault
in
the
foot
control
is
-
Reading
(infinite)
suspected,
first
carry
out
test
L.
Connect
the
multimeter
to
the
foot
con-
trol,
and
switch
to
the
range
ohms.
a)
Foot
control
not depressed.
Running
of
main
motor
Needle
stop
down
b)
Depress
the
foot
control
at
the
rear
-
Reading
10
k9
(needel
stop
down).
c)
Depress
the
foot
control
slowly
at
the
-
Reading
varies
rom
4
toO
k9
front.
Important:
If the
foot
control
is
defective,
open
the
foot
control
cover.
Carry
out
tests
a),
b)
and
c)
on
both
contacts.
If
these
give
correct
readings,
replace
the
cord
reel.
If
a
fault
persists,
then
change
the
regulater
housing.
0