BFT ECOSOL - MOTOR CONNECTIONS; SINGLE GATE OPERATION WIRING; DUAL GATE OPERATION WIRING

BFT ECOSOL
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BFT PHOBOS BT AND
IGEA BT GATE
OPERATORS ONLY
When installing dual gate where the gates overlap (or has a lock mechanism), it is important that the
motor that needs to open first is wired to MOTOR 2 terminals.
During the open cycle, MOTOR 2 starts first (MOTOR 1 has a delayed open start). During the close
cycle, MOTOR 1 starts first (MOTOR 2 has a delayed close start).Both delays can be independently adjusted
from 1 to 29 seconds. Please refer to page
24
24 for further instructions.
When installing a single leaf gate operator, the motor leads must be wired to MOTOR 2 terminals and
LIBRA controller must be configured to single gate operation. Please refer to page 26 for further
instructions.
SINGLE GATE OPERATION
DUAL GATE OPERATION
MOTOR 2
OPENS FIRST
CLOSES SECOND
MOTOR 1
OPENS SECOND
CLOSES FIRST
USE 16 AWG OR BETTER, STRANDED WIRES
USE 16 AWG OR BETTER, STRANDED WIRES