NOTE: If more than one device needs to be wired to the STOP input, they must be wired in series
START / CLOSE INPUT
STOP / RESET BUTTON
3-BUTTON STATION (open, stop, close)
The Start/Close input can be used for a single push button operation to open, stop and close commands
The Stop button also resets the controller if two consecutive physical obstructions are detected.
This is a NORMALLY CLOSED contact. The factory installed jumper must be removed for stop
button to operate.
REMOVE FACTORY
INSTALLED JUMPER
A 3-button station can be hard-wired using the START/CLOSE as close input. This input must be defined
as CLOSE ONLY INPUT at the controller. See page 25 (START-CLOSE) for directions.
CONTROL WIRING20
www.BFTGateOpeners.com | (800) 878-7829