1) Remove the battery of main panel
2) Keep Long pressing without release until battery
are re-load & 10 times beep sounds firstly & 4 times beep
sounds emits again,Then release pressing. Done.
Note:
After Restore factory Setting, all sensors including
remote control are all deleted. The main panel is on
disarming status.
12. FAQ
12.1 Tommy’s Office
Tom:
I install LED 1 pair Door sensor for zone 1 where is my
office back door. I hope it will alarm immediately if
someone opens after i arm the system. And keeps it silent
after i disarm it. How to set zone 1 features?
LOVLOY Answer:
Set Zone1 to be Ordinary Mode.
1) Long press & key [1] immediately, then the LED
indicator of zone 1 on main panel will keep flashing,
means entering the process of setting of zone1.
2) Short press key [1] which means you choosed mode 1-
ordinary mode
3) Then short press key [1] which means you choosed no
arming delay
4) The main panel will emit a long beep sound that
indicates your setting is done.
5) Finally press to quit setting.
12.2 Jenny’s Cute Cafe
Jenny:
I run a small caf downtown.There are 2 important place,
Zone 1 is the warehouse back door which i never open,so
i hope it will alarm no matter i arm or disarm the system
when someone break in there. And the second important
area is the entrance of my caf(Zone2). While i am at the
work(Disarm), I it would prompt me with doorbell tone
when customer came in. While i go off work (Arm),it will
alarm with siren when some one break in . How to set ?
LOVLOY Answer:
Set Zone1 to be emergency Mode:
Long press & key [1] + short press key [2] + short
press key [1] + to quit.
Set Zone 2 to be Welcome Mode.
Long press & key [2] + short press key [4] + short
press key [1 or 2] + to quit
12.3 Molly’s Home
Molly:
I’m a housewife, i stay at home most of the time. The
balcony is my zone3, i need it alarm delay 30seconds
after arming, and keep silent after disarming. The gate is
my zone 4, i need it to be alarm with doorbell sound no
matter in the status of arm/disarm.How to set zone 3 and
zone 4 features?
19 20