100K NTC or PT1000
When using 100K NTC, pull-up resistance is 4.7K, when using PT1000, pull-up
resistance is 2.2K, set sensor type to 1 for 100K NTC +4.7K pull-up resistance, 1022 for
PT1000 + 2.2K pull-up resistance. (Note: this method has a much lower accuracy than the
MAX31865 in reading temperature.)
#define TEMP_SENSOR_0 1
#define TEMP_SENSOR_1 1
#define TEMP_SENSOR_BED 1
BLTouch
//#define Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN //
#define BLTOUCH // Enable bltouch