Binder FD240-230V - User Manual

Default Icon
69 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Issue 03/2019 Art. No. 7001-0026
Operating Manual
Translation of the original operating manual
BD / BD-UL (E2) Incubators with natural convection
ED / ED-UL (E2) Drying and heating ovens with natural convection
FD / FD-UL (E2) Drying and heating ovens with forced convection
with microprocessor temperature controller
Modell Model version Art. No. Modell Model version Art. No.
BD 23
BD023-230V 9010-0187
ED 240
ED240-230V 9010-0101
BD023UL-120V 9010-0189 ED240UL-208V 9010-0167
BD 53
BD053-230V 9010-0081
ED400
ED400-230V 9010-0075
BD053UL-120V 9010-0179 ED400UL-208V 9010-0168
BD 115
BD115-230V 9010-0088
ED720
ED720-230V 9010-0076
BD115UL-120V 9010-0181 ED720UL-208V 9010-0169
BD 240
BD240-230V 9010-0095
FD 23
FD023-230V 9010-0194
BD240UL-120V 9010-0183 FD023UL-120V 9010-0196
BD400
BD400-230V 9010-0073
FD 53
FD053-230V 9010-0082
BD400UL-120V 9010-0176 FD053UL-120V 9010-0128
BD720
BD720-230V 9010-0074
FD 115
FD115-230V 9010-0102
BD720UL-120V 9010-0177 FD115UL-120V 9010-0129
ED 23
ED023-230V 9010-0190/0191
FD 240
FD240-230V 9010-0104
ED023UL-120V 9010-0192/0193 FD240UL-208V 9010-0130
ED 53
ED053-230V 9010-0078/0079
ED053UL-120V 9010-0131/0132
ED 115
ED115-230V 9010-0096/0097
ED115UL-120V 9010-0164/0165
BINDER GmbH
Address: Post office box 102, 78502 Tuttlingen, Germany Phone: +49 7462 2005 0
Fax: +49 7462 2005 100 Internet: http://www.binder-world.com
E-mail: info@binder-world.com Service Hotline: +49 7462 2005 555
Service Fax: +49 7462 2005 93 555 Service E-Mail: service@binder-world.com
Service Hotline USA: +1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific: +852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS: +7 495 988 15 16

Table of Contents

Questions and Answers

  • A
    Alexander KelleyAug 17, 2025
    Why is my Binder FD240-230V not working?
    • J
      Jonathan WileyAug 17, 2025
      Your Binder Climate chamber might not be working due to several reasons. First, check the connection to the power supply. Second, the chamber fuse might have responded, so check it and replace it if needed. If it responds again, contact BINDER service. Finally, the controller could be defective, in which case you should also contact BINDER service.
  • D
    Danielle NewtonAug 19, 2025
    What to do if Binder FD240-230V set-point temperature is not reached?
    • G
      gperryAug 19, 2025
      If the set-point temperature isn't reached in your Binder Climate chamber, ensure the chamber door is completely closed. Also, inspect the door gasket and replace it if it’s defective. Calibrate and adjust the controller. Finally, check the power supply to ensure the voltage is correct (115V or 230V).
  • J
    Jay TuckerAug 22, 2025
    Why Binder FD240-230V Climate chamber doesn’t heat up but controller display working?
    • L
      lisadeleonAug 22, 2025
      If your Binder Climate chamber isn’t heating up, and the red heating control light is off but the controller display is working, it could be due to the timer being run off. Program the timer or switch to continuous operation. Another cause might be a defective semiconductor relay, in which case you should contact BINDER service.
  • A
    Albert HaleyAug 25, 2025
    What to do if Binder Climate chamber isn't working and the red alarm light is on?
    • M
      Michelle MoodyAug 26, 2025
      If your Binder Climate chamber isn't working and the red alarm pilot lamp is lit, it could be that the safety device class 2 has turned off the chamber. Let the chamber cool down and then press the RESET button. Also, the safety device class 2 might be defective, in that case contact BINDER service.
  • T
    Tommy RamirezAug 28, 2025
    Why is my Binder FD240-230V heating permanently?
    • D
      Derrick EvansAug 28, 2025
      If your Binder Climate chamber is heating permanently and not maintaining the set-point, the controller may be defective, in that case contact BINDER service. Alternatively, the controller might need calibration and adjustment.
  • M
    Mary CookAug 30, 2025
    How to fix high temperature and red alarm on Binder FD240-230V?
    • A
      Alexandra RojasAug 30, 2025
      If the temperature inside your Binder Climate chamber is too high and the red alarm light is on, the safety device class 3.1 may have been triggered. Check the settings of the temperature set-point and of the safety device class 3.1.
  • S
    Steven ColemanSep 2, 2025
    Why does my Binder Climate chamber take longer to heat up?
    • B
      Bryan MillerSep 2, 2025
      If you're experiencing deviations from the indicated heating-up times with your Binder Climate chamber, it might be because the chamber is fully loaded. Try loading the chamber with fewer items or allow for longer heating-up times.
  • K
    Katie BeckerSep 5, 2025
    Why is my Binder FD240-230V Climate chamber in stand-by mode?
    • S
      Sandra WhiteSep 5, 2025
      If your Binder Climate chamber is without function and only the green 'stand-by' LED is lit, the chamber is likely in stand-by mode. Press the ON/OFF button until the display lights up.
  • M
    Mark RodriguezSep 7, 2025
    What to do if Binder FD240-230V Climate chamber fan is not working?
    • N
      Nathan SingletonSep 7, 2025
      If the fan in your Binder Climate chamber isn’t turning or is turning too slowly, the fan might be defective, in that case contact BINDER service.
  • D
    Donna DorseySep 12, 2025
    Why does my Binder FD240-230V controller return to normal display?
    • K
      Kayla RivasSep 12, 2025
      If the controller on your Binder Climate chamber returns to the Normal Display from any level, it's likely because no button was pressed for approximately 30 seconds. Repeat your entries, entering the values more rapidly.

Summary

Safety Instructions

General Safety for Installation and Operation

Essential safety guidelines for setting up and using the chambers.

Intended Use of Chambers

Defines the authorized applications and limitations for the chambers.

Chamber Description and Overview

Delivery, Handling, and Installation

Safe Lifting and Transportation

Guidelines for safely lifting, moving, and transporting chambers.

Installation Location and Ambient Conditions

Requirements for the installation site, environmental conditions, and chamber spacing.

Equipment Installation

Electrical Connection

Details on power connection requirements, plugs, and voltage compatibility.

Startup Procedures

Turning On the Chamber

Step-by-step guide to powering on and initializing the chamber.

Controller Operation

Temperature Set-Point Entry (No Ramp)

Setting temperature set-points without using the ramp function.

Temperature Set-Point Entry (With Ramp)

Setting temperature set-points when a temperature ramp is active.

Time Functions: Continuous and Timer Operation

Managing continuous operation and timer settings for chamber cycles.

User Level Settings and Access

Accessing and modifying user-configurable settings like temperature units.

Temperature Safety Devices

Class 2 Safety Device (ED, FD)

Function, setting, and checks for Class 2 temperature safety devices.

Class 3.1 Safety Device (BD)

Function, setting, and checks for Class 3.1 temperature safety devices.

Maintenance, Cleaning, and Service

Maintenance Intervals and Service

Recommendations for regular maintenance and service by authorized personnel.

Cleaning and Decontamination Procedures

Instructions for cleaning and decontaminating the chamber after use.

Troubleshooting Guide

Technical Description and Data

BD Model Technical Data

Technical specifications for BD series chambers.

ED Model Technical Data

Technical specifications for ED series chambers.

Binder FD240-230V Specifications

General IconGeneral
BrandBinder
ModelFD240-230V
CategoryClimate chamber
LanguageEnglish