MP
-
FR ESSAI
COPYRIGHT BIO
-
UV
-
20/01/2009
MARQUE, MODELES ET BREVETS DEPOSES - PRODUITS EXCLUSIFS
PAGE
19
PRECONISATIONS DE CONTROLES ET MAINTENANCE PREVENTIVE
0 CHANGEMENT DES LAMPES UV EN FIN DE VIE :
- SOIT AFFICHAGE DU MONITEUR MILLENIUM III :
INTENSITE UV <50%
- SOIT TAUX DE CHLORE COMBINE DANS LE BASSIN
OPERATIONS A CHAQUE
CHANGEMENT DE
LAMPE UV
AU MINIMUM 1
FOIS PAR AN
CONTROLE DE L’ETAT GENERAL DU
REACTEUR UV
1 REMPLACEMENT DES JOINTS
QUADRING
OBLIGATOIRE OBLIGATOIRE
2 CONTROLE DE LA PRESENCE DES
CALES TEFLON DE GAINE QUARTZ
OBLIGATOIRE
3 NETTOYAGE OU REMPLACEMENT DE
LA GAINE QUARTZ
OBLIGATOIRE
4 REMPLACEMENT DES RACLEURS DE
NETTOYAGE
PRECONISE
5 NETTOYAGE DU CAPTEUR UV OBLIGATOIRE OBLIGATOIRE
6 CONTROLE DU FONCTIONNEMENT
DU DEBITMETRE
OBLIGATOIRE
7 CONTROLE DE FONCTIONNEMENT
DES VENTILATEURS :
- NETTOYAGE DES GRILLES
- REMPLACEMENT DES FILTRES (SI
CONCERNE)
PRECONISE
OBLIGATOIRE
8 ETALONNAGE DU CAPTEUR UV UNIQUEMENT LAMPE NEUVE, GAINE QUARTZ
PROPRE OU NEUVE, CAPTEUR UV NETTOYE
9 REMPLACEMENT DU SILENCIEUX
PNEUMATIQUE
EN CAS DE CORROSION UNIQUEMENT
10
CONTROLER LA MISE A LA TERRE DU
REACTEUR
11
CONTROLER LE FONCTIONNEMENT
DU THERMOSTAT DANS L’ARMOIRE
ELECTRIQUE
PRECONISE
12
CONTROLER LE FONCTIONNEMENT
DU DISJONCTEUR
PRECONISE
13
CONTROLER LE SERRAGE :
- DES BORNIERS DANS L’ARMOIRE
- DES CONNECTEURS
- DES CONNEXIONS DES LAMPES UV
PRECONISE