BK Precision 1687B - Remote Control Command Set; Basic Remote Commands: Voltage, Current, Presets

BK Precision 1687B
42 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27
Command line format: COMMAND<parameter1><parameter2>…[CR]
Current value will have one decimal place for models 1687B and 1688B, and two
decimal places for Model 1685B.
Command code &
Return value
Function Example
Input command:
VOLT{<voltage>}[CR]
Return value:
OK[CR]
Set voltage level
<voltage> = 000-XXX
Input command:
VOLT010[CR]
Return value:
OK[CR]
Sets voltage level to 1.0 V
Input command:
CURR{<current>}[CR]
Return value:
OK[CR]
Set current level
<current> = 000-XXX
Input command:
CURR025[CR]
Return value:
OK[CR]
Sets current level to 2.5 A
Input command:
PROM{<preset 1
voltage>}{<preset 1
current>}{<preset 2
voltage>}{<preset 2
current>}{<preset 3
voltage>}{<preset 3
current>}[CR]
Return value:
OK[CR]
Set power supply
preset memory values
<preset X voltage> =
000-XXX
<preset X current> =
000-XXX
Input command:
PROM011022033044055066
Return value:
OK[CR]
Sets preset 1 voltage and current
to 1.1 V and 2.2 A, preset 2
voltage and current to 3.3 V and
4.4 A, and preset 3 voltage and
current to 5.5 V and 6.6 A
Input command:
GETS[CR]
Return value:
[voltage][current][CR]
OK[CR]
Get voltage and
current setting values
from power supply
[voltage] = 000-XXX
[current] = 000-XXX
Input command:
GETS[CR]
Return value:
025051
OK
Indicates voltage setting is 2.5 V
and current setting is 5.1 A