20
ELECTRICAL SPECIFICATIONS
Accuracy is expressed as:
±
(% of reading + no. of least significant
digits) at 23
±5
and <75% R.H.
Model 879:
Resistance (Parallel mode)
Test Frequency: 100 / 120 Hz
Range
Maximum
Display
Accuracy
Specified Note
@100 Hz
@120Hz
10M
9.999M
2.0%+8 *3 2.0%+8 *3 After open cal.
2000K
1999.9K
0.5%+5 0.5%+5 After open cal.
200K
199.99K
0.5%+3 0.5%+3 -
20K
19.999K
0.5%+3 0.5%+3 -
2000
1999.9
0.5%+3 0.5%+3 -
200
199.99
0.8%+5 0.8%+5 After short cal.
20
19.999
1.2%+40 1.2%+40 After short cal.
Test Frequency: 1K / 10K Hz
Range
Maximum
Display
Accuracy
Specified Note
@1K Hz
@10KHz
10 M
9.999M
2.0%+8 * 3 3.5%+10 * 3 After open cal.
2000 K
1999.9K
0.5%+5 2.0%+10 After open cal.
200 K
199.99K
0.5%+3 1.5%+5 -
20 K
19.999K
0.5%+3 1.5%+5 -
2000
1999.9
0.5%+3 1.5%+5 -
200
199.99
0.8%+5 2.0%+10 After short cal.
20
19.999
1.2%+40 2.5%+200 After short cal.
Notes:
1.
This specification is based on the measurement performed at the test socket.
2.
DUT (Device Under Test) & Test leads be properly shielded to GUARD if
necessary.
3.
This specification is based on battery operation.