G5 Weighing Instrument
5-3
5. Input Data
Byte
Size
Description
Note
0 1 Instrument error 8
1 1 Instrument Status
8
2 1 Instrument State
8
3 1 Command acknowledge
8
4 1 Command error
8
5 1 Level status 8
6 1 Setpoint status 8
7 1 Input and Output status 8
8 – 9 2 Error code 8
10 11 2 Scale status 8
12 15 4 Gross weight 1, 2
16 19 4 Net weight 1, 2
20 23 4 Flow rate 1, 3
24 27 4 Input signal 1, 4
28 31 4 Level 1 1, 2, 3
32 35 4 Level 2
1, 2, 3
36 39 4 Level 3
1, 2, 3
40 43 4 Level 4
1, 2, 3
44 47 4 Setpoint 1
1, 2, 3
48 51 4 Setpoint 2
1, 2, 3
52 55 4 Setpoint 3
1, 2, 3
56 59 4 Setpoint 4
1, 2, 3
60 63 4 Preset tare 1, 2
64 67 4 Acc. weight Low
1, 5
68 71 4 Acc. weight High
1, 5
72 75 4 Analog Output
1, 6
76 79 4 Aux. analog input
1, 7
80 81 2 Clock, year 8
82 1 Clock, month
8
83 1 Clock, day
8
84 1 Clock, hour
8
85 1 Clock, minute
8
86 1 Clock, second
8
87 1 Not used
8
88 1 No of decimals in weight values 8
89 1 No of decimals in flow rate 8
90 - 105 16 Spare 9