Vehicle Interface of Integrated Communication Optical Module (ICOM)
Page 8
User Guide
of 29
Copyright © BMW AG / ICOM User Guide
Version 1.0/ Februar 08
4.2
ICOM A
Fig. 2 ICOM A
4.2.1. Operating and storage conditions
Electrical operation:
Power supply KL30: 8V 18V
Max. current consumption: 1.5 A (including ICOM B)
Environmental conditions during operation:
Ambient temperature range: C ... +45°C
Relative atmospheric humidity at max. 25°C: 10% ... 80%, non-condensing
Temperature gradient: 5°C/h
Environmental conditions for mount:
Ambient temperature range: -20°C ... +60°C
Relative atmospheric humidity at max. 25°C: 10% ... 80%, non-condensing
Temperature gradient: 5°C/h