Electrical data
Charging cable: Type 2 cable: up to 32 A / 400 VAC
as per EN 62196-1 and EN 62196-2
Protection class: I
Device's IP protection class: IP54
Protection against mechanical impact: IK08
Mechanical data
Dimensions (W x H x D) 366 x 455 x 202 mm (without connector)
Weight: approx. 8 kg (depending on version)
Assembly (stationary): On the wall or on the column
Ambient conditions
Use: Indoor and outdoor use
Operating temperature at 16 A: -25 °C to +50 °C
without direct sunlight
Operating temperature at 32 A: -25 °C to +40 °C
without direct sunlight
Temperature properties: This is not a safety device, it is just an operating
function. The specified operating temperature
range must not be exceeded.
Within the specified operating temperature
ranges the devices will provide the charging
current continuously.
In order to increase the charging availability,
the charging current level is reduced to 16 A
if the temperature is exceeded. The charging
cycle may subsequently also be shut down. The
charging cycle is continued, and the charging
current value is increased again after cooling.
40