5.2.10 Beam centering
Adjust the XY centering knob to make the focal point in the center of the nozzle by low-power dotting.
Tape
Fail
Relative position of laser beam
pass
The conditioned laser
beam must be in the
center of the nozzle.
X/Y
adjustment
screw