BT50/BT60/BT65 BOMAG 27
4.11 Changing the oil in the tam-
per foot
Change the oil at operating temperature.
Ensure strict cleanliness.
Tilt the tamper backwards.
Fig. 4
Clean the oil drain plug (Fig. 4), screw it out
and drain the oil off.
Environmental hazard!
Catch the old oil and dispose of environmen-
tally.
Check the seals on the drain plug, replace if
necessary.
Screw the oil drain plug in and tighten it.
Fig. 5
Stand the tamper on the foot area.
Clean the filler plug (Fig. 5) and screw it out.
Fill in new oil
BT 50 = 0,75 l (0.198 USgal)
BT 60 = 0,75 l
BT 65 = 1,0 l (0.264 USgal)
BT 70 = 1,0 l
Screw the filler plug back in with a new sealing
ring.
For quality of oil refer to the paragraph on
fuels and lubricants.
Fig. 6
Clean the inspection glass (Fig. 6) and check
the oil level.
The oil level must reach the middle of the
inspection glass, top up oil if necessary.
Maintenance every year