Technical information and reports
AW 4 | 5 | 7 OR-S – 6721866761 (2023/06)
22
Table 7 Technical data single phase heat pump
Max. cooling capacity at A35/W7 kW 3,03 3,67 3,88
EER at A35/W7 2,56 2,49 2,44
Max. cooling capacity at A35/W18 kW 4,36 5,25 5,50
EER at A35/W18 3,37 3,20 3,11
Cooling capacity at A35/W18, nominal kW 2,93 3,47 3,82
EER at A35/W18, nominal 3,74 3,74 3,70
Electrical details
Power supply 230V 1N AC 50Hz 230V 1N AC 50Hz 230V 1N AC 50Hz
Protection index IPX4D IPX4D IPX4D
Fuse size
1)
A 16 16 16
Maximum power consumption A+2/W35 kW 1,34 2,21 2,51
Maximum power consumption A35/W7 kW 1,18 1,47 1,54
Maximum power consumption A35/W18 kW 1,29 1,64 1,77
Performance factor cos phi with maximum output >0,99 >0,99 >0,99
Max. number of compressor starts 6 6 6
Max. current A 7,5 12 13,1
Starting current A 7,5 12 13,1
Air and noise generation
2)
Maximum air flow m³/h 1160 1320 1670
Nominal air flow m³/h 1160 1320 1670
Sound pressure level at a distance of 1 m
3)
dB(A)323434
Sound power (ErP)
4)
dB(A) 40 42 42
Max. sound power - day dB(A) 51,2 53 57,7
Max. sound power - Low-noise operation 1, A7/W55 dB(A) 46 50 50
COP - Low-noise operation 1, A-7/W35 3,02 2,64 2,62
Power output - Low-noise operation 1, A-7/W35 kW 2,61 4,20 4,40
Max. sound power - Low-noise operation 2, A7/W55 dB(A) 43 48 48
COP - Low-noise operation 2, A-7/W35 2,92 2,66 2,70
Power output - Low-noise operation 2, A-7/W35 kW 2,34 3,53 3,83
Max. sound power - Low-noise operation 3, A7/W55 dB(A) 43 46 46
COP - Low-noise operation 3, A-7/W35 2,97 3,06 3,12
Power output - Low-noise operation 3, A-7/W35 kW 2,20 3,22 3,39
Max. sound power - Low-noise operation 4, A7/W55 dB(A) 40,5 41,6 43,8
COP - Low-noise operation 4, A-7/W35 2,89 2,91 3,15
Power output - Low-noise operation 4, A-7/W35 kW 1,98 2,32 2,64
Tonality addition - day
5)
dB 0 0 0
Tonality addition - Low-noise operation 3
5)
dB 0 0 0
General details
Refrigerant
6)
R290 R290 R290
Refrigerant charge kg 0,95 0,95 0,95
CO
2
(e) ton 0,003 0,003 0,003
Maximum temperature of flow, heat pump only °C 75 75 75
Installation altitude above sea level Up to 2000 m above sea level
Dimensions (W x H x D) mm 1100x800x540 1100x800x540 1100x800x540
Weight kg 143 143 143
1) Fuse class gL/C
2) Low-noise operation 1 - 4 is selected on the system controller
3) EU No 811/2013
4) Sound power level in accordance with EN 12102 (Nominal A7/W55), tolerance +/- 2dB
5) DIS47315/150257, April 2004 and following requirements of TA Lärm
6) GWP100 = 3
Unit 4 OR-S 5 OR-S 7 OR-S