Conettix Ethernet Communication Module Configuration | en 19
Bosch Security Systems, Inc. Installation and Operation Guide 2016.08 | 08 | F.01U.266.226
TCP/UDP Port Number
Default: 7700
Selection: 0 to 65535
This parameter sets the local port number on which the module listens for in-coming network
traffic. This port is also the source port for outgoing communication.
The TCP/UDP Port is typically configured as 7700 when the control panel is communicating
with a central station receiver, RPS, Automation or Remote Security Control. Port numbers are
assigned in various ways based on three ranges:
System Ports: 0 to 1023
User Ports: 1024 to 49151
Dynamic or Private Ports: 49152 to 65535
Note: In order to limit unwanted traffic, select a number above 1023.
Legacy TCP Automation Enable
Default: No
Selection: Yes, No
When enabled, a single TCP connection with no security is allowed.
TCP Keep Alive Time
Default: 45
Selection: 0 – 65 (0: Disable, 1 - 65: Keepalive Time in sec)
Select how many seconds the unit waits during a silent connection before attempting to see if
the currently connected network device is still on the network. If there is no response, it
drops the connection.