Conettix Ethernet Communication Module System overview | en 9
Bosch Security Systems, Inc. Installation and Operation Guide 2016.08 | 08 | F.01U.266.226
3.2 Bus address settings
The address switch determines the bus type and the module’s address on the bus. The control
panel uses the address for communications. Use a slotted screwdriver to set the address
switch.
Notice!
The module reads the address switch setting only during module power up. If you change the
setting after you apply power to the module, you must cycle the power to the module in order
for the new setting to take effect.
The B426 address switch provides the value for the module's address. The figure below shows
the address switch setting for address 1. Refer to the following table for panel-specific
settings.
Figure3.3: Address switch set to address 1
Control panels Switch
position
Control panel
address
Bus type Function
B9512G/B8512G, B6512/
B5512/B4512/B3512, GV4,
Solution 2000/3000
1 1 SDI2 Automation, Remote
Programming, or
Reporting
B9512G/B8512G, GV4,
Solution 2000/3000
2 2
GV4, GV3, GV2, D9412G/
D7412G/D7212G v6.3 or
higher
3 80 SDI Automation
GV4, GV3, GV2, D9412G/
D7412G/D7212G v6.3 or
higher
4 88 Reporting or Remote
Programming
GV4, GV3 5 92
FPD-7024 v1.06+,
DS7240V2, DS7220V2, Easy
Series V3+, AMAX Series,
CMS Series
6 134 Option
DS7400Xi 7 13
DS7400Xi 8 14 Reporting
FPD-7024, AMAX Series,
CMS Series
9 250 Reporting or Remote
Programming
Tab.3.1: B426 address switch settings