20 en | Configuration Conettix Ethernet Communication Module
2016.08 | 08 | F.01U.266.226 Installation and Operation Guide Bosch Security Systems, Inc.
5.3.5 Advanced Network Settings page
Figure5.4: Advanced Network Settings page
Legacy Panel Mode
Default: 0 (Disable)
Selections: 0, 1
0: Legacy Panel Mode is disabled.
1: Legacy Panel Mode is enabled.
This option allows the module to support legacy control panels that communicate using
Datagram Mode 0. When Legacy Panel Mode is enabled, the module uses the Local Port
parameter as both the source port and destination port for communication.
The control panels that use Legacy Panel Mode are:
– GV2 v7.05 and lower
– D9412G/D7412G/D7212G v6.99 and lower
– DS7400XiV4
Port 77EE Configuration Enable
Default: No
Selections: Yes, No
Yes: The network configuration port is enabled.
No: The network configuration port is disabled.
The Conettix D6200 Programming/Administration Software uses this port to find devices on
its local network.