Product description
5
Compress 3000 AWES – 6720892204 (2020/06)
3.2 Information on the indoor unit
The AWES indoor units are intended for installation inside the building
and connection to the outdoor unit.
Possible combinations:
Table 3 Selection table for wall mounted heat pump indoor units AWES
AWES is equipped with an integrated electric booster heater.
3.3 Declaration of Conformity
The design and operation of this product comply with
European Directives and the supplementary national
requirements. Conformity has been demonstrated by the CE
marking.
You can ask for a copy of the Declaration of Conformity for this product.
Please refer to the contact address on the back cover of these
instructions.
3.4 Type plate
The data plate of the indoor unit is on the control device behind the
cover. It contains information on the part number and serial number and
also the date of manufacture of the device.
3.5 Product overview
Fig. 2 Components and pipework connections of the indoor unit with
electric booster heater
[1] Installer module
[2] Resetting the overheating protection
[3] Circulation pump
[4] Electrical heater
[5] Automatic air vent valve (VL1)
[6] Cable feed for sensor, CAN-BUS and EMS BUS
[7] Heat transfer medium out to ODU outdoor unit 3/8" (Liquid)
[8] Heat transfer medium in from ODU outdoor unit 5/8" (Gas)
[9] Flow to heating system
[10] Pressure gauge
[11] Drain of the pressure relief valve
[12] Return from the heating system
[13] Cable feed for power supply
AWES Outdoor unit (ODU)
2-6 4
2-6 6
8-15 8
8-15 11s/t
8-15 13s/t
8-15 15 s/t