Installation
27
Bosch Condens 5000W – 6 720 646 195 (2018/10)
If fitting the outer seal from outside the building, slide the outer wall
seal onto the terminal as shown.
Fig. 39 Telescopic flue installation
For more information refer to the 60/100 horizontal flue kit instruction
manual.
Additional notes and reminders
Ensure that all cut lengths are square and free from burrs.
The flue is sealed when assembled correctly and the components are
pushed fully home.
The flue is set at an angle of 3° or 52mm per metre length.
Fig. 40 Slope for condensate disposal withing the flue system
4.5.2 Flue terminal plume re-direction
The flue discharge can be re-directed allowing some plume redirection
control, alternatively, a complete plume management system can be
fitted to the flue terminal.
Re-directing the flue discharge
Refer to figure 41.
1. Refit the terminal end [2] and secure with screws [1].
2. Loosen screws [3] and rotate the entire outlet assembly to redirect
the plume. Tighten screws [3] to secure in the required position.
The flue terminal outlet has built-in stops to limit rotation for horizontal
fluing to allow condensate to run back into the boiler for safe disposal. Do
not attempt to force beyond the limit stops.
Fig. 41 Plume re-direction
1.
1.
1.
2.
6720643895-33.1Wo
3.
4.
110
6720644842-10.1Wo
2m
1m
52mm
104mm
1
2
1.
3.
2.
3
1
±80°
180°
6720643895-34.1Wo