Table of contents
3
Condens 7000 FP – 6721846699 (2022/12)
11.8 Cleaning the burner and heat exchanger . . . . . . . . . . .43
11.8.1 Clean the burner. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43
11.8.2 Clean the heat exchanger. . . . . . . . . . . . . . . . . . . . . . . .43
11.9 Inspecting the burner electrodes . . . . . . . . . . . . . . . . .46
11.10 Testing the differential pressure switch . . . . . . . . . . . .47
11.11 Replacing components. . . . . . . . . . . . . . . . . . . . . . . . . .47
11.11.1 Removing the air/gas ratio control valve . . . . . . . . . . .47
11.11.2 Changing the gas filter . . . . . . . . . . . . . . . . . . . . . . . . .47
11.11.3 Removing the fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
11.11.4 Replacing components according to the service
life . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
11.12 Refitting detached parts . . . . . . . . . . . . . . . . . . . . . . . .49
11.12.1 Refitting parts removed . . . . . . . . . . . . . . . . . . . . . . . .49
11.12.2 Fitting the fan. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
11.12.3 Fitting the ventilation air collector and air/gas
ratio control valve. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
11.12.4 Installing the burner . . . . . . . . . . . . . . . . . . . . . . . . . . .50
11.12.5 Fitting the gas line to the gas valve. . . . . . . . . . . . . . . .51
11.12.6 Installing the ventilation air unit . . . . . . . . . . . . . . . . . .51
11.13 Check for leaks during operation. . . . . . . . . . . . . . . . . .51
11.14 Checking the ionisation current. . . . . . . . . . . . . . . . . . .51
11.15 Completing inspection and maintenance . . . . . . . . . . .52
11.15.1 Removing measuring devices . . . . . . . . . . . . . . . . . . . .52
11.15.2 Installing casing parts . . . . . . . . . . . . . . . . . . . . . . . . . .52
11.15.3 Checking the gas/air ratio. . . . . . . . . . . . . . . . . . . . . . .52
11.15.4 Confirming inspection and maintenance . . . . . . . . . . .52
12 Emergency operation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
12.1 Resetting faults in emergency mode . . . . . . . . . . . . . . .52
13 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
13.1 Recognising the operating condition and clearing
faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
13.2 Resetting pressure monitor . . . . . . . . . . . . . . . . . . . . . .53
13.3 Calling up the fault history . . . . . . . . . . . . . . . . . . . . . . .54
14 Operating and fault displays. . . . . . . . . . . . . . . . . . . . . . . . . . .55
14.1 Control unit status indicators. . . . . . . . . . . . . . . . . . . . .55
14.2 Service displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
14.3 Control unit fault displays . . . . . . . . . . . . . . . . . . . . . . .56
14.4 Status indicator of the burner control unit.. . . . . . . . . .64
15 Check temperature switch . . . . . . . . . . . . . . . . . . . . . . . . . . . .65
16 Testing the differential pressure switch. . . . . . . . . . . . . . . . .65
16.1 Test the continuity of the differential pressure
switch at negative pressure . . . . . . . . . . . . . . . . . . . . . .65
16.2 Testing the differential pressure switch for
continuity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66
17 Appendix . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
17.1 Technical data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67
17.2 Sensor curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .69
17.2.1 Temperature sensor at digital burner control unit . . . .69
17.3 Hydraulic resistance. . . . . . . . . . . . . . . . . . . . . . . . . . . .70
17.4 Connection diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . .70
17.4.1 Control unit connection diagram. . . . . . . . . . . . . . . . . .70
17.4.2 Burner control unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
17.4.3 Diagrammatic representation of supply air/flue
gas monitor and gas tightness . . . . . . . . . . . . . . . . . . . .71
17.5 Conversion of vol.% CO2 into vol.% O2 for burner
setting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 71
17.6 System commissioning report. . . . . . . . . . . . . . . . . . . . 72
17.7 Inspection and maintenance protocols. . . . . . . . . . . . . 73
17.8 Data Protection Notice. . . . . . . . . . . . . . . . . . . . . . . . . . 77

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Condens 7000 FP and is the answer not in the manual?

Bosch Condens 7000 FP Specifications

General IconGeneral
BrandBosch
ModelCondens 7000 FP
CategoryBoiler
LanguageEnglish

Related product manuals