D1265 | Installation Guide | 5.0 Specifications
.
Bosch Security Systems, Inc. | 11/11 | F01U169129-05 9
5. Enter the security company’s phone number and
click OK. The new number appears in the
appropriate User cell.
Figure 14: RPS: User Name Change
4.4 Update and Reset the Control Panel
1. When you are done with RPS, click the Save
button. If RPS is not already online with the
control panel, start a communication session and
send the programming changes to the control
panel.
2. When you are ready to end the online session,
click the Disconnect button and check the Rest
Panel box on the End Session dialog for the
programming changes to take effect.
Figure 15: RPS End Session Dialog
3. To close RPS, click the X button in the upper right
corner twice.
5.0 Specifications
Table 3: D1265 Specifications
Nominal Voltage 12 VDC
Wiring
Maximum resistance 11 Ω
Standby Current
Idle: 135 mA
Max*: 300 mA
Dimensions
(H x W x D):
12.2 cm x 12.0 cm x 3.0 cm
(4.8 in. x 4.7 in. x 1.2 in.)
Weight 0.24 kg (8.5 oz.)
Environmental Intended for indoor use
Operating
Temperature
0°C to +49°C
(+32°F to +120°F)
Relative Humidity 85% + 2% @ +49°C (+120°F)
Enclosure Color Bosch White
Enclosure Material Plastic (ABS)
* With speaker and display backlight at maximum.