D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 18.0 Installer Menu
.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09 111
Port Number (seconds)
B91x/B92x keypads Configuration of Port number
1. Enter the installer passcode, and then go to the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [2] Network > [2] Enhanced Comm Parms menu
option. The keypad displays the Enhanced Comm Parms option.
3. Press [ENTER] to edit the enhanced comm parms option. The options scroll through in
succession.
4. Use the [PREV] and [NEXT] buttons to toggle between the address, port #, poll rate, and
encryption options.
5. Press [ENTER] to edit the Port number parameter.
6. When the keypad shows Parameter Saved, escape from the menu.
B93x/B94x keypads Configuration of Port number
1. Enter the installer passcode, and then open the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [2] Network > [2] Enhanced Comm Parms menu
option. The keypad displays the enhanced comm parms option as well as the current default
value.
3. Press the softkey for the Port number option.
4. Use /[PREV] or /[NEXT] to go to the path you wish to edit.
5. Press the Edit softkey to change programming.
6. Press the Save softkey.
When the keypad shows Parameter Saved, escape from the menu.
Poll Rate
B91x/B92x keypads Configuration of Network Address, Poll Rate (seconds), and Port Number
1. Enter the installer passcode, and then go to the [1] Installer menu.
2. Go to the [1] Program > [1] Reporting > [2] Network > [2] Enhanced Comm Parms menu
option. The keypad scrolls the Network Address, Port Number, and Poll Rate for the selected
Enhanced Comm path.
3. Use the [PREV] or [NEXT] key to go to the path you wish to edit.
4. Press [ENTER] to edit the selected Enhanced Comm option. The keypad asks if you wish to
edit the address.
5. Press [ENTER] to edit the network address. The existing address and an editing cursor show.
6. Delete existing characters, if necessary, and then enter the new phone number Press [ENTER]
to save the address. The keypad shows Parameter Saved, and asks if you wish to edit the
address.
7. Press [PREV]. The currently configured poll rate shows, and the keypad asks if you wish to edit
the poll rate.
8. Press [ENTER] to edit the poll rate. The existing poll rate and an editing cursor show.
9. The [ESC] key acts as a [Backspace] key. Press [ESC] to delete the characters, and then enter
the new numbers.
10. Press [ENTER] to save the poll rate. The keypad shows Parameter Saved and asks if you wish to
edit the poll rate.
11. Press [PREV]. The currently configured port number shows, and the keypad asks if you wish to
edit the port number.
12. Press [ENTER] to edit the port number. The existing port number and an editing cursor show.