Installation
Figure 14 illustrates a system with six POPITs assigned in programming to each of five master zones in the ZONEX program
file, and only five POPITs installed for Master Zone 5. A “missing” POPIT condition will be displayed when COMMAND 44
is entered in the D1252A. If the POPIT is assigned to a D8112G1/G2 protective zone programmed for controlled zone
response (burglary) and the D8112G1/G2 is armed, the “missing” POPIT condition causes a system alarm. If the D8112G1/
G2 is disarmed, the system goes into a trouble condition. If the POPIT is assigned to a D8112G1/G2 protective zone
programmed for 24 hour zone response (fire, panic, holdup, etc.) the “missing” POPIT indicates a trouble condition.
MISSING
POPIT
2.5 Z1POINTS 6
2.12 Z8POINTS 00
PROGRAMMED
2.6 Z2POINTS 6
2.7 Z3POINTS 6
2.8 Z4POINTS 6
2.9 Z5POINTS 6
2.10 Z6POINTS 00
2.11 Z7POINTS 00
MASTER ZONE 1: 6
MASTER ZONE 2: 6
MASTER ZONE 3: 6
MASTER ZONE 4: 6
MASTER ZONE 5: 5
INSTALLED
Figure 14: Missing POPIT
Figure 15 illustrates a system with six POPITs assigned in programming to each of five master zones, and seven POPITs
installed for master zone 5. An “extra” POPIT condition will be displayed when [COMMAND 44] is entered at the D1252A.
The “extra” POPIT condition is annunciated only through the D1252A Command Center, and does not initiate a report to
the central station.
EXTRA
POPIT
2.5 Z1POINTS 6
2.12 Z8POINTS 00
PROGRAMMED
2.6 Z2POINTS 6
2.7 Z3POINTS 6
2.8 Z4POINTS 6
2.9 Z5POINTS 6
2.10 Z6POINTS 00
2.11 Z7POINTS 00
MASTER ZONE 1: 6
MASTER ZONE 2: 6
MASTER ZONE 3: 6
MASTER ZONE 4: 6
MASTER ZONE 5: 7
INSTALLED
Figure 15: Extra POPIT