Do you have a question about the Bosch Denoxtronic 2.1 and is the answer not in the manual?
Type | Denoxtronic 2.1 |
---|---|
Manufacturer | Bosch |
Model | Denoxtronic 2.1 |
System Voltage | 12V / 24V |
Operating Voltage | 9V - 32V |
Operating Temperature | -40°C to +85°C |
Protection Class | IP6K9K |
Communication | CAN |
Communication Interface | CAN bus |
Explains the structure, meaning, and consequences of warning notices for user safety and hazard prevention.
Lists and explains the various symbols used within the documentation to convey information and warnings.
Instructs users to observe and maintain the legibility of warning notices displayed directly on the product.
Highlights critical information for using the components and emphasizes the need to study ESI[tronic] repair instructions.
Directs users to comprehensive safety instructions in separate ESI[tronic] repair documents for safe operation.
Specifies that the test sets are exclusively for testing and repairing the AdBlue supply module type Denoxtronic 2.1.
Recommends qualified and trained personnel for testing/repairs and suggests user training at the AA training center.
Overview of the test device 0 986 613 880 for testing and repairing AdBlue supply modules.
Describes the adapter module 0 986 610 160 used as an interface for tests.
Details the test adapter 0 986 610 180 for setting test parameters and values.
Explains the gas manifold 0 986 610 970 for leakage tests using forming gas.
Covers the pressure gauge 0 986 610 510 for testing system operating pressures.
Details the procedure for attaching the pressure gauge to the test device.
Explains the mounting support 0 986 611 249 for positioning the AdBlue supply module.
Describes the base plate 0 986 613 866 for attaching the AdBlue delivery module.
Details the sealing device 0 986 610 905 for testing the AdBlue delivery module housing for leakage.
Explains the test dosing module 0 986 610 464 for testing the metered amount.
Describes the beaker set 0 986 610 460 for measuring return flow and metered amount.
Covers the scale 0 986 610 838 used for measuring return flow and metered amounts.
Details the weight 0 986 610 839 used for calibrating the scale.
Explains the extractor device 0 986 610 818 for removing the dosing valve.
Covers hydraulic hose assemblies needed for function tests and troubleshooting.
Provides instructions for applying stickers to the test device for initial setup.
Details the Testo gas detector used for leakage tests on the AdBlue delivery module.
Covers the voltage stabilizer required for optimum measurements with the Bosch voltage regulator.
Explains the hand pump 1 687 222 191 for testing leaks in the supply module housing.
Covers ESD protective equipment, such as wrist straps, to prevent damage to electronic components.
Details the use of forming gas 5 (5% H2, 95% N2) as a test medium for leakage tests.
Describes the Denoxtronic test solution mixture and its shelf life for testing.
Details how to check exhaust gas sampling hoses for damage and when they need replacement.
Provides the procedure for calibrating the scale 0 986 610 838 using the calibration weight.
Recommends periodic checks of the calibration weight 0 986 610 839 by a recognized workshop.
Details the annual function test procedure for the safety valves of the gas manifold 0 986 610 970.
Provides step-by-step instructions for exchanging the battery in the hand pump 1 687 222 191.
Covers visual inspection and function testing of the sealing device 0 986 610 905 and its safety valves.
Instructs to hand over all documentation when passing on the Denoxtronic 2.1 unit.
Warns about oils and greases being hazardous to water and requiring proper disposal.
Provides guidelines for dismantling, sorting, and recycling Denoxtronic 2.1 and its accessories.