Reference Guide
for the DS7400Xi (Ver. 4+)
Control/Communicator
Turning On (arming) your System using the DS7445/DS7445i
or DS7447/DS7447E Keypad
Normal Arming [PIN] + [On]
Perimeter Arming, no entry delay [PIN] + [No Entry] +
[Perimeter Only]
Perimeter Arming, with entry delay [PIN] + [Perimeter Only]
Maximum Security Arming [PIN] + [No Entry] + [On]
Custom Arming [PIN] + [#] [4]
Set Delayed Arming [PIN] + [#] [9] [9] and enter
number of hours from
current time to the desired
arming time.
Extend Automatic Arming [PIN] + [OFF] during pre-
arm time
Force Arming Enter an arming
command followed by
[Bypass]
Zone Bypass [PIN] + [Bypass] followed
by the Zone number.
[PIN] +[Bypass] [*] to clear
ALL Bypasses.
Turning Off (disarming) your System
Enter your [PIN] followed by [Off]
Commands for other System Features
Chime Mode [PIN] + [#] [7]
System Walk Test [PIN] + [#] [8] [1]
Read Event History [PIN] + [#] [8] [9]
Battery Test [PIN] + [System Reset]
Communicator Test [PIN] + [#] [8] [2]
Fire Reset [PIN] + [System Reset]
Remote Program Dial-out [PIN] + [#][8] [3]
Remote Program Answer [PIN] + [#] [8] [6]
Battery/Sounder Test [PIN] + [#] [8] [5]
Error Display [PIN] + [#] [8] [7]
Error Display Reset [PIN] + [System Reset]
Fire Walk Test [PIN] + [#] [9] [1]
To Silence a Fire Trouble/Alarm [PIN] + [Off]
To Clear a Fire Trouble Display [PIN] + [System Reset]
Access Control
Enter your [Access Control PIN] followed by [Off]
Keypad Quick Reference Guide
NOTE: For additional information on operating this system, consult the DS7400Xi (Ver. 4+) User’s Guide (P/N: 43851) and section 7
of this Reference Guide.
DS7447/DS7447E
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
12345678
91011
12 13
14 15
16
Armed
Status
Power
Fire
Perimeter
Supervisory
Bell Silenced
Trouble
1 23
456
789
0
*
#
On
No
Entry
System
Reset
Bypass
Only
Perimeter
Off
TEST WEEKLY
Armed
Status
Power
Fire
DS7445/DS7445i

Table of Contents

Other manuals for Bosch DS7400Xi

Questions and Answers:

Bosch DS7400Xi Specifications

General IconGeneral
Partitions8
CommunicationPSTN, IP
Battery Backup7Ah
Operating Temperature0°C to 49°C (32°F to 120°F)
Power SupplyAC 16.5V, 25VA

Summary

Quick Reference Guide

System Arming Procedures

Guides for turning the system on and arming it using keypad commands.

System Feature Commands

Lists commands for accessing various system features and functions.

System Specifications

Physical, Environmental, and Capacity Details

Details enclosure size, operating temperature, zones, keypads, partitions, and users.

Power, Load, and Battery Requirements

Specifies power input, auxiliary power, outputs, max load currents, and backup battery calculation.

Installation and Wiring

Enclosure and Control Installation Procedures

Step-by-step instructions for installing the enclosure and control/communicator unit.

Control Terminal Wiring and Hardware Layout

Diagrams and explanations for connecting control terminals and system hardware layout.

System Operation and Testing

Emergency Procedures and Alarm Handling

Guides on identifying alarms, silencing, and responding to emergencies.

System Testing Procedures

Procedures for performing zone, battery, communicator, and fire walk tests.

System Programming

Programmer Mode and Data Entry

How to enter programmer mode, read, and enter program addresses and values.

Zone Configuration and Functions

Programming zone functions, types, outputs, partitions, and keypad assignments.

Timer, Report, and Communication Settings

Configuring delays, reports, phone numbers, and pager settings.

Troubleshooting Guide

Keypad, Reporting, and Zone Problem Resolution

Common issues with keypads, reporting, zones, and their solutions.

System Fault Diagnosis and Resolution

Troubleshooting power, communication, bus, and general system faults.