DSA E-Series (E2700) Turning on the power and checking for problems in an E2700 controller-drive tray configuration | en 71
Bosch Sicherheitssysteme GmbH Installation manual 2015.10 | V2 | DOC
L5 An auto-code synchronization (ACS) failure has been detected,
which results in a suspended controller state.
L6 An unsupported host interface card has been detected, which
results in a suspended controller state.
L7 A sub-model identifier either has not been set or has been
mismatched, which results in a suspended controller state.
L8 A memory configuration error has occurred, which results in a
suspended controller state.
L9 A link speed mismatch condition has been detected in either the
ESM or the power supply, which results in a suspended controller
state.
Lb A host interface card configuration error has been detected, which
results in a suspended controller state.
LC A persistent cache backup configuration error has been detected,
which results in a suspended controller state.
Ld A mixed cache memory DIMMs condition has been detected, which
results in a suspended controller state.
LE Uncertified cache memory DIMM sizes have been detected, which
result in a suspended controller state.
LF The controller has locked down in a suspended state with limited
symbol support.
LH A controller firmware mismatch has been detected, which results
in a suspended controller state.
LJ The controller does not have enough memory to support the
configuration, which results in a suspended controller state.
LL The controller cannot access either midplane SBB EEPROM, which
results in a suspended controller state.
Ln A canister is not valid for a controller, which results in a suspended
controller state.
LP Drive port mapping tables are not detected, which results in a
suspended controller state.
Lr A non field replaceable unit has been replaced, which results in a
suspended controller state.
Lt A configuration data base corruption has been detected, which
results in a suspended controller state.
LU The start-of-day (SOD) reboot limit has been exceeded, which
results in a suspended controller state.
S1 The controller detects a checksum failure in EEPROM, which
results in a suspended controller state.